Industrial replacement referenceSource-backed records · No compatibility guesswork

Baldor-Reliance three-phase enclosed motor · live detail API

EM4104T

30HP, 1760RPM, 3PH, 60HZ, 286T, 1056M, TEFC, F1

Output30.000 HP @ 60 HZActual speed1760 rpmFrame286TEnclosureTEFCBaldor product page ↗

Manufacturer-published motor data

Electrical and mechanical specifications

64 live detail fields
Catalog number
EM4104T
UPC
781568103302
Output @ frequency
30.000 HP @ 60 HZ
Actual speed
1760 rpm
Synchronous speed
1800 RPM @ 60 HZ
Phase
3
Frequency
60.00 Hz
Voltage
460.0 V @ 60 HZ · 230.0 V @ 60 HZ
Current
38.000 A @ 460.0 V · 76.000 A @ 230.0 V
Frame
286T
Frame material
Iron
Enclosure
TEFC
Duty
CONT
Full-load efficiency
93.6 %
Service factor
1.15
Insulation class
F
Mounting arrangement
F1
Motor type
1056M
Poles
4
Shaft diameter
1.875 IN
Ambient temperature
40 °C
Inverter status
Inverter Ready
Motor standard
NEMA
Agency approvals
CURUSEEV · NEMA PREMIUM · NEMA PREMIUM (OLD LOGO)
Published list text
EM4104T | 30HP, 1760RPM, 3PH, 60HZ, 286T, 1056M, TEFC, F1 | 781568103302

Verification boundary

What still needs to match

Do not infer interchange
Mechanical interfaceConfirm complete NEMA frame suffix, mounting, shaft geometry, envelope, conduit-box orientation, and driven-equipment clearance.
Electrical supplyVerify voltage, frequency, phase, full-load current, starting method, protection, and available fault/current characteristics.
Duty and controlsCheck actual speed, service factor, efficiency, starts per hour, thermal duty, VFD suitability, and operating speed range.
EnvironmentConfirm enclosure, ambient, altitude, washdown/corrosion/hazard requirements, and current Baldor-Reliance documentation.

Related Baldor-Reliance motors

Same frame

8