CEM2559T-4

125HP, 1775RPM, 3PH, 60HZ, 405TC, 4488M, OPSB

Output125.000 HP @ 60 HZActual speed1775 rpmFrame405TCEnclosureOPSBBaldor product page ↗

Manufacturer-published motor data

Electrical and mechanical specifications

54 live detail fields
Catalog number
CEM2559T-4
UPC
781568982716
Output @ frequency
125.000 HP @ 60 HZ
Actual speed
1775 rpm
Synchronous speed
1800 RPM @ 60 HZ
Phase
3
Frequency
60.00 Hz
Voltage
460.0 V @ 60 HZ
Current
143.000 A @ 460.0 V
Frame
405TC
Frame material
Steel
Enclosure
OPSB
Duty
CONT
Full-load efficiency
95.4 %
Service factor
1.15
Insulation class
F
Mounting arrangement
F1
Motor type
4488M
Poles
4
Shaft diameter
2.875 IN
Ambient temperature
40 °C
Inverter status
Inverter Ready
Motor standard
NEMA
Agency approvals
CURUSEEV · NEMA PREMIUM · NEMA PREMIUM (OLD LOGO)
Published list text
CEM2559T-4 | 125HP, 1775RPM, 3PH, 60HZ, 405TC, 4488M, OPSB | 781568982716

Verification boundary

What still needs to match

Do not infer interchange
Mechanical interfaceConfirm complete NEMA frame suffix, mounting, shaft geometry, envelope, conduit-box orientation, and driven-equipment clearance.
Electrical supplyVerify voltage, frequency, phase, full-load current, starting method, protection, and available fault/current characteristics.
Duty and controlsCheck actual speed, service factor, efficiency, starts per hour, thermal duty, VFD suitability, and operating speed range.
Open enclosure environmentConfirm ventilation, ambient, contamination/drip exposure, guarding, and whether an open motor is suitable for the installation.