Industrial replacement referenceSource-backed records · No compatibility guesswork

Baldor-Reliance three-phase open motor · live detail API

GNEM2524T

15HP//11KW, 1180//980RPM, 3PH, 60//50HZ, 284

Output11.000 KW @ 50 HZActual speed1185 rpmFrame284TEnclosureOPSBBaldor product page ↗

Manufacturer-published motor data

Electrical and mechanical specifications

60 live detail fields
Catalog number
GNEM2524T
UPC
781568586020
Output @ frequency
11.000 KW @ 50 HZ
Actual speed
1185 rpm
Synchronous speed
1200 RPM @ 60 HZ
Phase
3
Frequency
50.00 Hz
Voltage
230.0 V @ 60 HZ · 208.0 V @ 60 HZ · 190.0 V @ 50 HZ · 460.0 V @ 60 HZ · 380.0 V @ 50 HZ
Current
48.000 A @ 190.0 V · 44.000 A @ 208.0 V · 42.000 A @ 230.0 V · 24.000 A @ 380.0 V · 21.000 A @ 460.0 V
Frame
284T
Frame material
Steel
Enclosure
OPSB
Duty
CONT
Full-load efficiency
91.7 %
Service factor
1.15
Insulation class
F
Mounting arrangement
F1
Motor type
4056M
Poles
6
Shaft diameter
1.875 IN
Ambient temperature
40 °C
Inverter status
Inverter Duty
Motor standard
NEMA
Agency approvals
UKCA · WEEE · NEMA PREMIUM (OLD LOGO) · CURUS · CE · NEMA PREMIUM · IE3
Published list text
GNEM2524T | 15HP//11KW, 1180//980RPM, 3PH, 60//50HZ, 284 | 781568586020

Verification boundary

What still needs to match

Do not infer interchange
Mechanical interfaceConfirm complete NEMA frame suffix, mounting, shaft geometry, envelope, conduit-box orientation, and driven-equipment clearance.
Electrical supplyVerify voltage, frequency, phase, full-load current, starting method, protection, and available fault/current characteristics.
Duty and controlsCheck actual speed, service factor, efficiency, starts per hour, thermal duty, VFD suitability, and operating speed range.
Open enclosure environmentConfirm ventilation, ambient, contamination/drip exposure, guarding, and whether an open motor is suitable for the installation.

Related Baldor-Reliance motors

Same frame

6