Industrial replacement referenceSource-backed records · No compatibility guesswork

1750 rpm input · archived catalog section 3.24

6090DA · 121:1

Published Cyclo 6000 double-reduction selection with 14.5 rpm output, 0.34 hp input rating, 1330 lb-in output torque, and 750 lb overhung-load value.

Nominal ratio121:1Output speed14.5 rpmOutput torque1330 lb-inCurrent catalog page ↗

Manufacturer selection record

Published rating data

Archived official catalog
Frame model
6090DA
Nominal ratio
121:1
Input speed
1750 rpm
Output speed
14.5 rpm
Input horsepower
0.34 hp
Output torque
1330 lb-in
Overhung load
750 lb
Published housing styles
H, F, V
Archive catalog
03.601.50.010
Current catalog listed
03.601.50.013

Replacement screening

Checks before specifying a replacement

Do not infer current fit
Current ratingRecheck this archived selection against the current Sumitomo catalog or configurator before ordering.
Full model identityConfirm every character of the installed unit's model code, reduction stages, housing, mounting, input, and output construction.
Mechanical interfacesVerify shafts, keys, flanges, feet, centerlines, envelope, rotation, and connected-equipment geometry.
Application dutyConfirm service factor, starting/shock load, radial and axial loads, ambient conditions, lubrication, and operating schedule.

Same frame model

Related published ratios